<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22015</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: ALE board still in reset
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>ThermoFlex</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The ALE board has been reset for some reason. Confirm proper operation of the ale
board. Re-seat the board (with the power off) and reset the ThermoFlex.
Watch for error messages as the ALE LCA file is downloaded during the startup sequence.
Check the power supplies to the ALE. Look for causes of static discharge which may
have reset the ALE board. Replace ALE board if no cause for the problem is found,
and return the ALE board to system engineer for diagnosis.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
This is not an operator-serviceable error. Call Creo response to log the error.
Reset the machine to continue production.
</text></DescriptionText>
</OperatorAction>
<Cause>
The ALE_RESET bit of the ale.version register has been set for some reason.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:51 2008 PST